Fire & Safety Solutions
At Scube Tech Services, we provide end-to-end Fire & Safety solutions that ensure early detection, quick response, and effective control of fire hazards across commercial, industrial, and residential buildings. Our systems are designed to protect lives, property, and critical infrastructure by integrating the latest in detection, suppression, and emergency response technology.

Addressable Fire Detection System
An Addressable Fire Alarm System precisely identifies the location of a fire incident by assigning a unique address to each connected device (smoke detectors, heat detectors, MCPs, etc.). This helps in:

Accurate pinpointing of the affected area.

Faster response time.

Advanced monitoring through fire alarm control panels

Integration with BMS, HVAC shutdowns, and emergency lighting systems.
Components include:

Smoke & Heat Detectors

Manual Call Points (MCP)

Notification Devices (Hooters, Sounders, Strobes)

Fire Alarm Control Panel (FACP)

Repeater Panels and Graphic Annunciators (optional)
Fire Suppression System
Fire suppression systems are designed to extinguish fires automatically or manually using specialized agents, minimizing damage and downtime. These systems are commonly used in data centers, electrical panels, server rooms, and high-risk industrial zones.
Types we offer:
safe for electronics, leaves no residue.
ideal for unoccupied areas like transformer rooms
uses fine water spray for cooling and fire control.
effective for flammable liquids in oil & gas facilities.
Why Choose Scube Tech Services?
- Certified and compliant with local fire safety standards
- Integration with IBMS, CCTV, PA & Emergency systems
- AMC, testing, training, and 24x7 emergency support
- Partnerships with leading OEMs in fire and life safety
Fire Extinguishers
Portable Fire Extinguishers provide the first line of defense in case of fire, especially for small-scale incidents. We supply, install, and maintain various types of ISI-certified extinguishers based on the fire risk category.

ABC Dry Powder

COâ‚‚

Foam

Water

Clean Agent
Devices Used
- Smoke Detectors (Ionization, Photoelectric)
- Heat Detectors (Fixed Temperature & Rate-of-Rise)
- Manual Call Points (Break Glass Units)
- Manual Call Points (Break Glass Units)
- Conventional Fire Alarm Control Panel
- Hooters/Sounders
- Fire Alarm Cables
- Zone Monitor Modules (for interfacing)
Fire Alarm Control PanelPanel
- The brains of the system
- Provides power to the system, monitors inputs and controls outputs through various circuits.
- Performs other functions as required by the appropriate code.
Addressable Fire Alarm System
Every device connected to the addressable system has its own unique address. When a fire is detected, the device’s address shows up on the main control panel, telling us exactly which device has been activated. This will enable us to find the exact location of a fire and extinguish it quickly.
- Each device (detector, pull station…) has a unique number assigned to it called the address for reporting alarms and troubles.
- Employs a Signaling Line Circuit (SLC) Loop along which all addressable input and output devices are connected to the fire alarm control panel.
- Addressable devices transmit an electronic message back to the Control Unit representing their state (Normal, Alarm, Trouble) when polled by the Control Unit.
Conventional Fire Alarm System
- The simplest type of control unit. Generally, a single circuit board contains a power supply, control, initiating and notification circuitry.
- Some models use auxiliary circuit boards to perform special functions.
- Input/output devices connect to dedicated circuits.
- Designated outputs occur when initiating signals are received.
- Limited special functions and capabilities.
Input Device
Input Device

Fire Alarm Hooter

Horns

Control Module

Horns Strain

Bells
Addressable Fire
Alarm Systems
Each device has a unique address, enabling the system to identify the exact location of a fire or fault, allowing quick and accurate response.
Key Features
- High scalability and flexibility
- Device-level monitoring and control
- Real-time diagnostics and logging
- Easy integration with BMS, HVAC, PA, Sprinkler, and Access Control systems
- Compliant with NFPA, IS, and international fire safety standards
Devices Used
- Addressable Smoke and Heat Detectors
- Multi-Sensor Detectors
- Addressable Manual Call Points
- Intelligent Control Panels (1-loop to multi-loop)
- Addressable Hooters with Flasher
- Loop Isolators
- Repeater Panels (for multi-building or high-rise towers)
Integration Capabilities
Scube Tech Services specializes in integrating Fire Alarm Systems with :
- Building Management System (BMS)
- Public Address/Voice Evacuation Systems
- Sprinkler and Fire Suppression Systems
- Access Control & Emergency Lighting Systems
Value-added Services
- Site Survey & Risk Assessment
- System Design and BOQ Preparation
- Installation & Wiring by Certified Technicians
- Testing, Commissioning, and AMC
- Fire NOC Documentation Assistance
- Client Training & System Handover
Our Strengths
- 10+ years of domain expertise
- Collaboration with top OEMs like Honeywell, Siemens, Ravel, GST, Agni, etc
- Project execution in IT Parks, Hotels, Hospitals, Warehouses, and Data Centers
- End-to-end compliance with IS2189 and NFPA codes
Typical Applications
- Corporate Buildings & Commercial Complexes
- Industrial Warehouses and Manufacturing Plants
- Educational Institutes & Hospitals
- High-rise Residential Societies
Our Brands Partners